Send command to device to execute (set)

Value should be in minutes

Possible values: 0 (disabled) and 1 (enabled)

Possible values:
0 – Online manual control mode;
1 – Online automatic control mode;
2 – Online automatic control mode with external temperature reading.

Possible value range: 5C - 30C

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

Possible values:
0 – Vicki operates in heating mode (default for the device);
1 – Vicki operates in cooling mode;

Applicable to certain device online operational modes
The desired temperature in Celsius degrees. The value must be greater than 0°C

Possible values:
0 – For the device to use the "Proportional control" algorithm;
1 – For the device to use the "Equal directional control" algorithm;

Possible values:
0 – Child lock is automatically disabled when the device goes offline.
1 – Child lock remains unchanged when the device goes offline.

Possible values:
0 – Deactivate force-attach
1 – Activate force-attach

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

Value should be in minutes

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

Value should be in minutes

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

Possible values: 0 (disabled) and 1 (enabled)

Possible values: 0 (disabled) and 1 (enabled)

The allowable full display refresh period range that can be set is (1hour – 24hours). The default value is 10hours

Set a time delay for sending the target temperature. The allowable delay range that can be set is(0sec. – 255sec). The default value is 10sec.

The allowable target temperature range that can be set is (5°C – 30°C).

In automatic mode, the heating state is on when the target temperature is above the measured temperature.

In sensor mode, the device only displays measurements from available sensors.

In deep sleep mode, the consumption of the device is significantly reduced.

Set the status of the PIR sensor to on or off (1/0).

Set the sensitivity of the PIR sensor. The default value is 20.

Set a flag to show/hide the current temperature on the display. Default is show (1)

Set a flag to show/hide the humidity on the display. Default is show (1)

Set a flag to show/hide the light intensity on the display. The default state is show. (1)

Set the initialization time period of the PIR sensor. Minimum value = 3sec. Default value = 3sec.

Set the measurement time period for motion detection by a PIR sensor. Minimum value = 3sec. Default value = 3sec.

It is used to periodically check for motion detected by the PIR sensor. When the period is set to 0, then it is constantly monitored for detected motion. Minimum value = 0sec. Default value = 54sec.

The blind period is used after motion is detected for how long to disable detection. Minimum value = 15sec. Default value = 10min.

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Behavior - 1-ON, 2-Blink fast, 3-Blink slow, 4-OFF

Volume - 0-min... 14-max, 15-OFF

Frequency - 0-1kHz, 1-1.5kHz ... 10-6kHz

Active Time - in seconds, min-1s,"0"- buzzer stay active until command or button is pressed

On Time - in milliseconds, resolution – 10ms

Off Time - in milliseconds, resolution – 10ms

Value should be in seconds. Resolution is 10s

Value should be in minutes

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Values should be in minutes, range 0-255, cannot be both 0

Led Id - 0-Led Open, 1-Led Close, 2-Led Leakage, 3-Led Flood

Behavior - 1-ON, 2-Blink fast, 3-Blink slow, 4-OFF

Volume - 0-min... 14-max, 15-OFF

Frequency - 0-1kHz, 1-1.5kHz ... 10-6kHz

Active Time - in seconds, min-1s,"0"- buzzer stay active until command or button is pressed

On Time - in milliseconds, resolution – 10ms

Off Time - in milliseconds, resolution – 10ms

Maximum allowable value is 15

Possible values: 0 (disabled) and 1 (enabled)

Value should be in minutes. Default value is 5

Default value for the device is 1850mV

Possible values: 0 (disabled) and 1 (enabled)

Value should be in minutes

Resolution is 10s. A zero value is forbidden. Default value is 30sec.

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Value should be in minutes

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Value should be in minutes

Possible values: 0 (disabled) and 1 (enabled)

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

The allowable target temperature range that can be set is (5°C – 30°C).

The allowable full display refresh period range that can be set is (1hour – 24hours). The default value is 10hours

Set a flag to show/hide the current temperature on the display. Default is show (1)

Set a flag to show/hide the humidity on the display. Default is show (1)

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Value should be in minutes

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

Value should be in minutes

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

"good-medium" - Good-medium CO2 zone boundary value in ppm

"medium-bad" - Medium-bad CO2 zone boundary value in ppm.

This value is used by the device for CO2 measurements compensation in order to get 400ppm in fresh air. This value is represented in ppm

Auto-zero period in hours. Default auto-zero period, after the factory auto-zeroing, is 192 hours (8 days). During this period the lowest measured CO2 value is accepted as 400ppm and the auto-zero value is obtained automatically. If The period is 0, automatic auto-zero function is disabled, but the obtained or set with command auto-zero value is still used internally.

Notification period, in minutes, when measured CO2 is inside the zone. 0 means notify once.

Used until the measured CO2 levels are inside the zone. In minutes.

Beeping (s) Loud periods (ms) Silent periods (ms)
Good Zone
Medium Zone
Bad Zone

Led Values - 0-None, 1-LED is constantly on for the given time duration, 2-Blink fast for the given time duration, 3-Blink slow for the given time duration.

Red Green Blue Duration (ms)
Good Zone
Medium Zone
Bad Zone

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

Value should be in minutes

When no uplink is received for the defined Watch-Dog Period (WDP), the device resets itself.

0 for disabled

"pCU" - Confirmed Uplinks

"pUU" - Unconfirmed Uplinks

Possible values: 0 (disabled) and 1 (enabled)

"good-medium" - Good-medium CO2 zone boundary value in ppm

"medium-bad" - Medium-bad CO2 zone boundary value in ppm.

This value is used by the device for CO2 measurements compensation in order to get 400ppm in fresh air. This value is represented in ppm

Auto-zero period in hours. Default auto-zero period, after the factory auto-zeroing, is 192 hours (8 days). During this period the lowest measured CO2 value is accepted as 400ppm and the auto-zero value is obtained automatically. If The period is 0, automatic auto-zero function is disabled, but the obtained or set with command auto-zero value is still used internally.

Used until the measured CO2 levels are inside the zone. In minutes.

The allowable full display refresh period range that can be set is (1hour – 24hours). The default value is 10hours

In deep sleep mode, the consumption of the device is significantly reduced.

Set the status of the PIR sensor to on or off (1/0).

Set the sensitivity of the PIR sensor. The default value is 20.

Set a flag to show/hide the current temperature on the display. Default is show (1)

Set a flag to show/hide the humidity on the display. Default is show (1)

Set a flag to show/hide the light intensity on the display. The default state is show. (1)

Set the initialization time period of the PIR sensor. Minimum value = 3sec. Default value = 3sec.

Set the measurement time period for motion detection by a PIR sensor. Minimum value = 3sec. Default value = 3sec.

It is used to periodically check for motion detected by the PIR sensor. When the period is set to 0, then it is constantly monitored for detected motion. Minimum value = 0sec. Default value = 54sec.

The blind period is used after motion is detected for how long to disable detection. Minimum value = 15sec. Default value = 10min.

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here